On-Line Analysis For Advanced Process Control At J. R. Simplot's Smoky Canyon Phosphate Mine
By W. Perkins
The Smoky Canyon Mine has recently installed a PROMPTED GAMMA NEUTRON ACTIVATION ANALYSIS (PGNAA) on-line analyzer as part of a long-term advanced process control program. The on-line analyzer was ada
Jan 1, 1996
-
On-Line Analysis Of Coal Ash In Flotation Slurries: A Laboratory Investigation
By S. K. Kawatra
With the increasing importance being placed upon modernizing the coal industry as a result of recent developments in the international energy balance, computer control has been and is being instituted
Jan 1, 1982
-
On-Line Analysis of Phosphate Rock Slurry by Prompt Neutron Activation Technique
By S. L. Zhu, Brij M. Moudgil, J. L. Pinault
Prompt neutron activation probe (PNAP) was evaluated to determine chemical composition of phosphate rock slurry in-situ. The technique was able to precisely analyze Ca, Si and H using a 252Cf source.
Jan 1, 1993
-
On-Line Bias And Froth Depth Measurement In Flotation Columns : A Promising Tool For Automatic Control And Real-Time Optimization
By J. Bouchard, V. Aubé, A. Desbiens, R. del Villar
The metallurgical performance of column flotation is determined by the concentrate grade and recovery. Although the former can be continuously measured using an on-stream analyzer, the latter must be
Jan 1, 2003
-
On-Line Coarse Particle Size Measurement -Industrial Testing
By C. L. Lin
A PC image-based on-line coarse particle size analyzer has been developed to measure particle size distributions under plant situations where overlapped particles are being transported on a moving bel
Jan 1, 1995
-
On-line Cyanide Analysis
By P. J. Hyde
Cyanide is a significant contributor to the cost of producing gold. Any reduction in consumption that can be achieved through more reliable measurement and/or more efficient management of dosing rates
Jan 1, 1995
-
On-Line Data Reconciliation By Minimization Of A Weighted Sum Of Squared Residuals And Node Imbalances
By Daniel Hodouin, Claude Bazin, Sami Makni
A method is proposed to perform on-line data adjustment and inference of unmeasured variables, using measured flowrates and on-stream assays in mineral processing plants. The algorithm minimizes a wei
Jan 1, 1995
-
On-Line Diagnostic Maintenance Systems For Continuous Mining Machines
By J. C. Cawley
Improvements in today's maintenance practices are mandatory as more complex and productive machines evolve in the mining industry. By keeping machine reliability high through improved maintenance
Jan 1, 1992
-
On-Line Diagnostic Maintenance Systems For Continuous Mining Machines (f04357ef-28a2-44a2-b5e5-3cf01cd8c0cc)
By J. C. Cawley
Improvements in today's maintenance practices are mandatory as more complex and productive machines evolve in the mining industry. By keeping machine reliability high, through improved maintenanc
Jan 1, 1991
-
On-Line Diagnostic Of Gold Leaching Parameters In A Laboratory Scale Simulation Of A Heap Leach System
By M. G. Irish, E. E. Vidal, M. J. Jahraus, P. R. Taylor
An experimental system has been designed to monitor on-line variations of leaching parameters in a closed circuit of cyanide leaching solutions and gold bearing ores. Experiments performed to deter-mi
Jan 1, 2004
-
On-Line Fragmentation Analysis for Grinding and Crushing Control
By Tom C. Palanglo, Norbert Maerz
Control of crushing and grinding circuits ideally requires continuous particle size measurements on both in- and outgoing streams. Until recently, size distributions could only be obtained by screenin
Jan 1, 2000
-
On-Line Imaging Of Aggregates For Process Control
By Michael Taylor, Thomas W. BoBo
Currently two of the most important characteristics of construction aggregates are (a) the particle size distribution (psd) and (b) the “shape” of the aggregate particles. The long established test me
Jan 1, 2005
-
On-Line Instrument For Coarse Particle Size Distribution Measurements
By James H. Vignos
An optical instrument designed for the on-line measurement of the size distribution of coarse particles (3-500 mm) being transported on a conveyor belt is described. Included is a discussion of the me
Jan 1, 1979
-
On-Line Material Balance for Flotation Plants
By Daniel Hodouin, Claude Bazin, Sami Makni
SCOTT COULTER: Thanks, Eric. Thank you all for coming. Our first speaker today is Claude Bazin. Claude received a degree in metallurgical engineering in 1980 from Laval University in Quebec. He worked
Jan 1, 1998
-
On-line measurement of slurry rheology in a thickener at a copper concentrator
By S. K. Kawatra, A. K. Bakshi
An on-line rheometer was developed to monitor the slurry rheology of a thickener underflow. The thickener processed a chalcopyrite flotation concentrate having a top particle size of 125 µm and a soli
Jan 1, 1999
-
On-Line Moisture Determination Of Ore Concentrates `A Review Of Traditional Methods And Introduction Of A Novel Solution'
By F. Rosenblum, P. Cancilla
The manual moisture determination methods employed today by mineral processing plants falls short in providing timely information required for automatic control. The costs associated with transporting
Jan 1, 2002
-
On-line Monitoring And Computer Control Of Heap Leach Systems
By James P. Sabogal
A control and monitoring system is being developed by Betz Laboratories for the heap leach process in gold recovery. Called Betz 14000GL, the system is designed to improve gold leaching and provide sa
Jan 1, 1998
-
On-Line Particle Analysis Of Aggregates
By R. Owen, T. Canty, C. Marks
The industrial vision system provides on-line 2D particle size analysis for aggregate slurries in both the overflow and underflow of hydrocyclones. This paper covers required vision system features a
Jan 1, 2002
-
On-Line Reconciliation Of Mineral Processing Data
By Daniel Hodouin, Claude Bazin, Sami Makni
Computer systems, installed in mineral processing, are designed to accumulate massive amounts of real-time data. Frequently these data are only partially processed because of the lack of adequate meth
Jan 1, 1993
-
On-Line Rheometer For Mineral Slurries
By S. K. Kawatra, A. K. Bakshi, T. C. Eisele
An on-line rheometer, suitable for use with slurries, has been developed at Michigan Technological University. This rheometer can be used with both Newtonian and non-Newtonian slurries, and produces c