Search Documents
Search Again
Search Again
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
-
Innovative Riverbank Erosion Control Retaining Wall System for the Brazos River
By Tracy Brettmann, Will Bohlen
An innovative retaining wall design consisting of tangent drilled shafts with supplementary seal piles was used to limit continuing bank erosion along the Brazos River in Southeast Texas. The riverban
Jan 1, 2018
-
Underpinning The Existing No. 1 Subway Line At The World Trade Center
By Richard Crockford
The World Trade Center (WTC) is located on the west side of Manhattan in New York City, approximately 0.5 miles north of Wall Street, and is owned and operated by the Port Authority of New York and Ne
Jan 1, 2008
-
Lateral Load Test on Piles with Large Free Stand
By P. V. Chandramohan
"In ports, piled berths are designed and constructed for berthing of ships with a finite draught. Piles in a bridge foundation also have a large free stand above scoured level. The piles of these stru
Jan 1, 2015
-
Anchored Pile Foundations In British Columbia
By Cory J. E. Yacyshyn
Anchored steel pipe piles are being used more frequently in British Columbia for shoreline projects such as public ferries, cruise ship docks, containership terminals and locally in the expansion of t
Jan 1, 2004
-
Design Optimization - Drilled Shafts Installed In Sand, Gravel And Cobble Formation
By Emad Farouz
The resistance of very dense glacial outwash formations consisting of sand, gravel and cobble formations can be quite high, and techniques for measuring the strength and deformation properties often c
Jan 1, 2006
-
A Critical Appraisal Of Is-Code Provisions For Pile Design ? Synopsis
By N. Som
The pile capacity in cohesive and granular soils depends on a number of parameters. The values of these parameters as recommended by Indian Standard Code of Practice vary over wide ranges. A designer
Jan 1, 1996
-
A Review Of Typical Foundations Used In The City Of Cleveland, OH
By David V. Lewin
Heavy structures in central Cleveland, Ohio, are supported on raft foundations, driven piles, or caissons. Settlements can be predicted and structures are designed to accommodate such settlements. On
Jan 1, 1985
-
Foundations On Karstic Limestone In Kuala Lumpur Malysia ? Synopsis
By J. M. Mitchell
Kuala Lumpur, Malaysia is underlain by karstic limestone. Firm clays, mudstones and siltstoncs of the Kenny Hill Formation overlie the limestone for about two thirds of the city. The remaining third h
Jan 1, 2010
-
Careful And Controlled Underpinning Methods In Restoration Of Damaged Houses In The Old Town Of Stockholm
By T. Iwanowski
Stress wave measurements and calculations are often used to make a safe determination of the bearing capacity and the integrity of driven piles. Some applications to the restoration of old buildings i
Jan 1, 1991
-
Installation Of Augerpiles In Low Headroom And Restricted Access Conditions
By Jim Steding
L.G. Barcus and Sons, Inc. recently completed a three-phase project for the expansion of Presbyterian Hospital in Albuquerque, New Mexico for McCarthy Construction Co., the Construction Manager for th
Jan 1, 2003
-
Drilled Piers In Coastal Plain Deposits
By J. Allan Tice
In the past fifteen to twenty years, the use of drilled piers to support high capacities in coastal plain deposits has become more and more common. With improved construction techniques and better und
Jan 1, 1988
-
Automated Installation Monitoring For Augercast And Driven Piles
By Garland Likins
Where soil conditions are favorable, augercast piles have significant economic advantages, but they also have some uncertainty due to the in construction methods. To confirm structural integrity, stat
Jan 1, 1999
-
Geographic Information Systems Technology Use in Tracking Quality Control in In Situ Barrier Wall Construction
By Robert Bachus, Jamey B. Rosen
"Abstract Large scale In Situ Barrier Wall Construction projects, specifically those related to earth dams, dikes, and levees, frequently require stringent quality control measures to ensure the succe
Jan 1, 2014
-
To Protect Pit-Wall By Means Of Chemical Grouting In Excavation Work Of Deep Foundation Pit
By Xiong Houjin
In the excavation works of some deep foundation pits within the boundaries of Guangdong Province of China, though some measures, such as steel sheet piles, diaphragm walls, etc. were taken to protect
Jan 1, 1991
-
Use of Porous Concrete in Secant Bored Pile Walls
By Matthias Pulsfort, Markus Herten, Rolf Breitenbücher, Claudia Fierenkothen
"Secant bored pile walls are frequently used as retaining walls in watertight excavations to cut off ground water aquifers and are subsequently exposed to ground water pressure loading in addition to
Jan 1, 2017
-
Soil Inclusions In Jet Grout Columns
By Timothy D. Stark
Jet grouting has increasingly become one of the ground improvement technologies used to address seepage concerns and to provide strength improvement of soils. The technique of jet grouting uses high p
Jan 1, 2009
-
Test Pile Program Carrier Pier And South Wharf Naval Station Puget Sound Everett, Washington
By David G. Winter
The first test pile for the carrier pier and south wharf at NAVSTA Puget Sound was driven on December 27, 1989, and the final pile was tested on February 26, 1990. Implementation and modification of t
Jan 1, 1990
-
Practical Soil Nail Wall Design And Constructability Issues
By Walter G. Kutschke
Four significant soil nail wall projects in the eastern United States were recently completed with a combined area of 175,000 square feet of finished shotcrete surface. These projects required the us
Jan 1, 2007
-
Pile Load Testing Of Helical Piles And Driven Steel Piles In Anchorage, Alaska
By Mohammed Sakr
The use of helical piles for permanent foundation applications has become a practical and feasible alternative to the traditional cast-in-place concrete or driven steel piles. Research and development
Jan 1, 2009
-
Monitoring And Quality Control Of A 100 Metre Deep Diaphragm Wall
By D. A. Bruce
To check the feasibility and the quality of a very deep diaphragm wall, a tern of adjacent panels has been constructed, up to a depth of 100 m, in the Milan sandy gravelly soil by means of a hydraulic
Jan 1, 1989