    Vertical Load Carrying Capacity Of Concrete Expanded Base Piles

    By Mustapha Zergoun

    This paper presents the results of load tests to assess the vertical load carrying capacity of concrete expanded base piles, or pressure injected footings, for various projects located near Vancouver,

    Jan 1, 2004

  • DFI
    Interactive Encased Stone-Column Foundation - Synopsis

    By P. M. Deshpande

    An interactive short column system is evolved as alternative to deep foundation system in deep layers of marine clay, the interaction of encased stone column and marine clay carry load without causing

    Jan 1, 1996

  • DFI
    Seven Mile Dam Retrofit - A Global Challenge

    By Arvindh Gupta

    BC Hydro proposed to improve the stability of the existing Seven Mile Dam with 54 corrosion protected, re-stressable anchors comprising 92/0.6? strands each, in phase 2 of the program. Being globally

    Jan 1, 2004

  • DFI
    Laterally Loaded Model Piles In Jointed Soft Rock Masses

    By B. Francis

    Literature provides only limited information regarding the behaviour of laterally loaded piles socketed into weak rock masses. A laboratory program, comprising a number of tests of scaled models of th

    Jan 1, 2004

  • DFI
    Optimisation Of Pile Type To Support Major Structures Above A Deep Sand Profile - Synopsis

    By P. Davies

    The Hillside Smelter presently under construction at Richards Bay, Republic of South Africa, will be, on completion, the fifth largest aluminium smelter in the world. The site selected for this plant

    Jan 1, 1996

  • DFI
    Slope Stabilization: Single Versus Staggered Piles

    By A. J. Metz, Roberto Nevarez

    One popular method to stabilize slopes is the use of deep foundation elements to support lateral loads from an unstable soil or rock mass. Drilled deep foundation elements are often selected due to lo

    Nov 1, 2023

  • DFI
    Use Of Cone Penetration Test (CPT) Results For Accurate Assessments Of Pile Capacities

    By Anand J. Puppala

    This paper provides information on various evaluation studies conducted to assess the CPT based interpretation methods. Salient findings from these evaluations are summarized. Additionally, a comprehe

    Jan 1, 2002

  • DFI
    Controlling Vibrations From Close-in Pile Driving

    By Patrick T, David K. Miller

    Driven piles are an effective and cost-efficient deep foundation method; however, when piles are driven near existing buildings and improvements, vibrations must be controlled to non-damaging levels.

  • DFI
    Time Effect Of Bearing Behavior Of Bored Pile Group In Un-Saturated Silty Soil ? Synopsis

    By J. L. Liu

    Long-term maintained load test on the bored pile group in unsaturated silty soil has been carried out. And the research on the time effects of bearing behavior of pile group has been done by the metho

    Jan 1, 2010

  • DFI
    Mobilisation Of Skin Friction In Bored Piles In Hong Kong ? Introduction

    By R. A. Fraser

    Large diameter (1.0 to 2.5m) bored piles have been widely used to support buildings and elevated roadways in Hong Kong. Most of these piles are founded on a hard bearing stratum such as granitic or vo

    Jan 1, 2010

  • DFI
    Deep Soil Mixing Use in Poland

    By Michal Topolnicki

    Deep Mixing Series: This article is the second keynote highlighted from DFI's virtual Deep Mixing Conference in 2021, for which Topolnicki served as a committeee co-chair Polish applications of deep s

    Apr 1, 2022

  • DFI
    Load Tests On Large Diameter Bored Piles In Cemented Sands

    By Nabil F. Ismael

    Load tests were carried out to examine the ultimate bearing capacity of short, large diameter bored piles in connection with the construction of a multistory building on the Arabian Gulf in Kuwait.

  • DFI
    Tension Tests On Driven Pipe Piles In Sand - Synopsis

    By Alan J. Lutenegger

    A series of tension tests were performed on prototype scale steel pipe piles at two sites to evaluate the influence of scale and pile plugging on the unit skin friction developed in axial tension. The

    Jan 1, 2000

  • DFI
    TBM Recovery Shaft Construction - SR-99 Tunnel

    By Lance Rasband, Richard Hanke, John Starcevich

    "The 17.4 meter (57 ft) diameter tunnel boring machine (TBM), the world’s largest at the time of her launch in 2012, locally referred to as “Bertha,” is stuck. Incapacitated due to mechanical failure

    Jan 1, 2016

  • DFI
    Session 7: Grouting Compaction Grouting For Sinkhole Repair at WAC Bennett Dam

    By James Warner

    Investigations of the sinkhole indicated that the loose, disturbed ground was completely encircled by dense competent core. This confinement substantially increased the effectiveness of the compaction

    Feb 10, 2003

  • DFI
    Keynote Lecture 6: Mitsuhiro Shibazaki Jet Grouting

    By Mitsuhiro Shibazaki

    Generally, water-soluble polymers are effective in convergence of water jet ejected from a nozzle as they add viscosity to water. However, excessive additional polymers (added to keep water viscous) c

    Feb 10, 2003

  • DFI
    No. 1 Queens Road - Melbourne, Australia

    By Tom George

    "INTRODUCTIONNo. 1 Queens Rd was an existing 10-storey office building founded on large pad footings. This project involved the construction of a 6-level, 15m (50-ft.) deep basement excavated immediat

    Jan 1, 2005

  • DFI
    Underpinning System Based On Preloaded Micropiling For Construction Of Additional Underground Floors

    By Wolfram Groh

    New underground floors comprising the complete footprint area of the building structure, were constructed under an existing building in sand, located in the Verdun district of Beirut / Lebanon. The wo

    Jan 1, 2002

  • DFI
    Suwanee American Cement Plant, Branford, Florida: A Case Study Of Large Diameter Continuous Flight Auger Design Build Foundations

    By Gordon King

    This paper presents a case study of large diameter continuous flight auger (CFA) piles and drilled shafts utilized for foundation support of a series of heavily loaded cement plant structures at the S

    Jan 1, 2003

  • DFI
    Dynamic Lateral Response Of A Full-Scale Pile Group

    By Kyle M. Rollins

    To improve our understanding of lateral resistance of pile groups, a series of lateral load tests were performed on a full-scale pile group using both static and dynamic loads. The pile group consiste

    Jan 1, 2002