Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
- 
                     Vertical And Lateral Load Tests On Driven And Cast-In-Place Piles ? Synopsis Vertical And Lateral Load Tests On Driven And Cast-In-Place Piles ? SynopsisBy G. Price The Building Research Establishment installed a base load cell in a driven cast-in-place pile prior to it being tested under vertical load. The monitored base loads were found to be significantly less Jan 1, 2010 
- 
                     Evaluation Of Achievable Column Diameter In Jet Grouting Evaluation Of Achievable Column Diameter In Jet GroutingBy Chu E. Ho Key variables that govern the jet cutting process are examined based on fundamental theories of jet hydrodynamics and soil mechanics. Under normal conditions of jet grouting operations, lift speed and Jan 1, 2006 
- 
                     Application Of PCC Piles On Soft Ground Improvement Of Expressways Application Of PCC Piles On Soft Ground Improvement Of ExpresswaysBy Hanlong Liu The construction process and load-bearing behaviors of Cast-in-place Concrete Thin-wall Pipe Piles are analyzed based on its application on Yan-Tong Expressway project. The low strain test, static loa Jan 1, 2006 
- 
                     Evaluating Excavation Support Systems To Protect Adjacent Structures (The 2010 Michael W. O?Neill Lecture) Evaluating Excavation Support Systems To Protect Adjacent Structures (The 2010 Michael W. O?Neill Lecture)By Richard J. Finno This paper presents an overview of methods that can be used to predict damage to buildings as a result of excavation-induced ground movements and describes an adaptive management approach for predicti Jan 1, 2010 
- 
                     "Underpinning By Jet Grouting" - Summary "Underpinning By Jet Grouting" - SummaryBy George K. Burke Underpinning of a structure has been traditionally expensive, time consuming, and, in many cases, caused as much settlement to the existing structure as it was trying to prevent. As underpinning is no Jan 1, 1991 
- 
                     Emplacement Techniques: Impervious And Pervious Wall Construction ? Summary Emplacement Techniques: Impervious And Pervious Wall Construction ? SummaryBy Fred C. Schmednecht For years, the strategy was to contain waste and in many applications, is still the recommended method. Recently, it has become acceptable to create filters below ground for the in-situ treatment of w Jan 1, 1999 
- 
                     Design Of Axially Loaded Compression Piles According To Eurocode 7 Design Of Axially Loaded Compression Piles According To Eurocode 7By Bauduin C. Besix The Eurocode 7 "Geotechnical Design" is based on "Limit State Design", tackling the uncertainties as much as possible at their source through: - selection of characteristic values of variables (load Jan 1, 2002 
- 
                     Concrete Overbreak Estimation and Analysis Errors in Bored Piles Concrete Overbreak Estimation and Analysis Errors in Bored PilesBy Nuno Cruz "The concrete overbreak estimation for bored piles provides the quantification of the shaft’s expansion beyond its theoretical volume. There are stability analysis methods that can be employed before Jan 1, 2017 
- 
                     Load Test Analysis On Augered Pressure Grouted Displacement Piles Load Test Analysis On Augered Pressure Grouted Displacement PilesBy Wei Zheng A pulverized coal fired power plant is being built in Osceola, Arkansas, along the Mississippi River. The subsurface soil conditions consist of a certain amount of very soft clayey silt and clay under Jan 1, 2007 
- 
                     Diaphragm Walls Seismic Design According to the Eurocodes Diaphragm Walls Seismic Design According to the EurocodesBy J. Matos e Silva "Abstract Although one can think that it is very low the probability of a seism occurrence during the execution of an excavation in an urban lot protected by a diaphragm wall curtain, reality shows th Jan 1, 2014 
- 
                     Time Dependent Open-End Pipe Pile Capacity Assessment By Dynamic And Quasi-Static Methods Time Dependent Open-End Pipe Pile Capacity Assessment By Dynamic And Quasi-Static MethodsBy Derrick D. Dasenbrock Three piers of a new river bridge are supported on 1.067 m diameter open-end steel pipe piles. At time of drive, and after pile re-strikes, high-strain dynamic capacity values at plan tip elevations, Jan 1, 2006 
- 
                     Full-Scale Field Investigations & Numerical Analyses of Innovative Seismic Composite Fiber Reinforced Polymer and Reinforced Grouted Helical Screw Instrumented Piles Under Axial & Lateral Monotonic & Cyclic Loadings Full-Scale Field Investigations & Numerical Analyses of Innovative Seismic Composite Fiber Reinforced Polymer and Reinforced Grouted Helical Screw Instrumented Piles Under Axial & Lateral Monotonic & Cyclic LoadingsBy M. Hesham El Naggar, Yasser Abdelghany "ABSTRACT: The axial and lateral monotonic and cyclic behavior of helical pile foundations was investigated and new innovative helical screw systems suitable for seismic loadings were developed and pa Jan 1, 2014 
- 
                     Comparison of a and ß Methods with CPT and Pile Load Test Data: A Case Study with Attention on Soil Setup Effects Comparison of a and ß Methods with CPT and Pile Load Test Data: A Case Study with Attention on Soil Setup EffectsBy Mohammadreza Khanmohammadi, Kazem Fakharian "AbstractIn driven piles, the gradual dissipation of excess pore water pressure and consequently the soil setup significantly contribute to increasing the pile capacity with time. The question is rise Jan 1, 2014 
- 
                     Application Of Augered, Cast-In-Place Displacement (ACIPD) Piles In New York City Application Of Augered, Cast-In-Place Displacement (ACIPD) Piles In New York CityBy Willie M. NeSmith Conventional augered, cast-in-place (ACIP) piles were introduced into the New York City area as a result of the damage to existing structures caused by pile driving operations. ACIP piles are often sp Jan 1, 2004 
- 
                     Present Developments In The Design Of Deep Foundations Present Developments In The Design Of Deep FoundationsBy Rolf Katzenbach The principle questions related to the design of deep foundations especially in soft soils are the stability and the cost optimised settlement reduction to prevent possible damages and to minimise the Jan 1, 2006 
- 
                     What Has Been Learned About Drilled Shafts From The Osterberg Load Test - Summary What Has Been Learned About Drilled Shafts From The Osterberg Load Test - SummaryBy Jorj O. Osterberg The Osterberg (O-Cell) Method makes it possible to separate the side shear resistance (skin friction) from end bearing. The O-Cell is placed on or near the bottom of a drilled shaft and after the conc Jan 1, 1999 
- 
                     Toward Understanding the Seismic Performance of Rigid Inclusions Toward Understanding the Seismic Performance of Rigid InclusionsBy J. Tanner Blackburn, James R. Gingery, Lisheng Shao Rigid inclusions consist of grout columns installed using displacement auger or vibrated tooling. The columns are typically installed in an array to provide support for footings, mats, or embankments. Jan 1, 2018 
- 
                     Experiences of High Strain Dynamics Pile Testing (HSDPT) in Accordance with EC7 in Sweden Experiences of High Strain Dynamics Pile Testing (HSDPT) in Accordance with EC7 in SwedenBy Ingemar Hermansson, Thomas Bjerendal, Mattias Grävare, Carl-John Grävare "AbstractHigh strain dynamic pile tests (HSDPT) on driven piles have been carried out on a routine basis in Sweden for more than 30 years. The Swedish Commission on Pile research established, in the e Jan 1, 2014 
- 
                     EFFC-DFI Geotechnical Carbon Calculator Project EFFC-DFI Geotechnical Carbon Calculator ProjectBy Vincent Joannes, Marine Lasne, Luca Brenelli, Colin Serridge, Inge van Baardwijk, Martin Stanley, Anthony Fisher, Mary Ellen Bruce, Tony Suckling, Pedro Avellanosa "Abstract The European Federation of Foundation Contractors (EFFC) and Deep Foundations Institute (DFI) developed a sector-specific carbon accounting methodology and associated “carbon calculator” for Jan 1, 2014 
- 
                     Design Of Drilled Shafts Supporting Sound Walls Design Of Drilled Shafts Supporting Sound WallsBy Ke Yang Drilled shafts are widely adopted as the foundation for sound walls. However, there has been a lack of uniformity in design and analysis methods and design criteria, in terms of factor of safety again Jan 1, 2007 
