Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization

Sort by

  • NIOSH
    Case History Of The Response Of A Longwall Entry Subjected To Concentrated Horizontal Stress

    By D. Oyler

    The National Institute for Occupational Safety and Health (NIOSH) Pittsburgh Research Laboratory (PRL), RAG Pennsylvania and Strata Control Technologies of Australia collaborated in an intensive study

  • NIOSH
    Evaluation Of Two-Phase Spray System For Airborne Dust Control In A Longwall Gallery

    By R. V. Ramani, B. K. Belle

    The increased effectiveness of a two-phase spray system (TPSS) over a single-phase spray system (SPSS) for dust suppression is reported in several laboratory studies. The dust collection efficiencies

  • NIOSH
    Investigation Of Fully Grouted Roof Bolts Installed Under In Situ Conditions

    By David Oyler, Craig Compton

    The The National Institute for Occupational Safety and Health (NIOSH) Pittsburgh Research Laboratory (PRL) is continuing to investigate the behavior of fully grouted roof bolts in the weak roof rock o

  • NIOSH
    Numerical Modeling Of The U1A Complex At The Nevada Test Site: Model Development And Comparison Of Different Drift Mining Options

    By R. Karl Zipf, Francois E. Heuze

    Stress analysis programs such as MULSIM/NL, LAMODEL, MinSim 2000, and EXAMINETAB are used in the mining industry to analyze stresses and displacements in coal mines, platinum mines, gold reefs, and ta

  • NIOSH
    Remote Monitoring of Mine Seismicity and Earthquakes Using Radio Telemetry, Computers, and the Internet

    By D. Denton, M. Stickney, R. Langston

    The National Institute for Occupational Safety and Health and the Stillwater Mining Company worked cooperatively with the Montana Bureau of Mines and Geology to develop a system that would collect sei

  • NIOSH
    Ranking Factors Impacting Survival During Coal Mine Fires

    By F. N. Kissell, C. D. Litton

    This study ranks the factors impacting survival during a coal mine fire. It bas already been established that reducing time delays is the most important factor in saving lives. Consequently every even

  • NIOSH
    A New Concept for Leak Testing Environmental Enclosure Filtration Systems

    By Michael Schmitz, John A. Organiscak

    ABSTRACT: A method (patent pending) has been developed to determine the quality of environmental cab filtration systems. This method utilizes specially configured filter cartridges to remove carbon di

  • NIOSH
    Worker Responses to Realistic Evaluation Training

    By M. Brnich, L. Mallett, C. Vaught, K. Kowalski

    This paper discusses the data collected during an emergency evacuation training exercise at an underground mine in the United States. The focus of this paper is on the human reaction to smoke and the

  • NIOSH
    Development Of A Through-The-Earth Monitor System

    The object of this program was to design and build a self-contained system for remote monitoring of the atmosphere in mines. The system developed uses the mine pager phone line as the primary communic

  • NIOSH
    Back Injury Control Measures For Manual Lifting And Seat Design

    By S. Gallagher, A. G. Mayton

    Back injuries account for a high proportion of lost workdays in the mining industry and are a leading cause of disability in mine workers. Two risk factors for low back injuries are manual lifting and

  • NIOSH
    Advances In Mine Emergency Communications

    By Jeff Kravitz, John Kovac, Wayne Duerr

    Since 198 1, Federal mining law has required every miner working in underground coal mines to have a self-contained, self-rescuer (SCSR) available for use in emergencies. Some miners that have escaped

  • NIOSH
    OFR 25-75 - Analytical Investigations Of Electromagnetic Location Schemes Relevant To Mine Rescue - Part I - Executive Summary

    By D. A. Hill

    This volume contains a summary of the results of past analyses on U.S. Bureau of Mines Contract No. H0122061 which are relevant to electromagnetic location in mine rescue situations. The analytical re

  • NIOSH
    A Review Of Occupational Silica Exposures On Continuous Mining Operations

    By Gerrit V. R. Goodman, Jeffrey M. Listak, John A. Organiscak

    Data on dust control practices, geology, and occupational exposures were gathered for approximately eighty underground continuous mining units. Despite silica contents in excess of 5%, nearly forty un

  • NIOSH
    A Multiplexed Phone System For Small Mines

    By James R. Means, George Bowser

    A new phone system was developed that provides eight full duplex communications channels over a single twisted shielded phone line, with no central switching station or line amplifiers. This system gr

  • NIOSH
    Coal Dust Particle Size Survey of U.S. Mines

    By Michael J. Sapko, Gregory M. Green, Harry C. Verakis, Kenneth L. Cashdollar

    The National Institute for Occupational Safety and Health (NIOSH) and the Mine Safety and Health Administration (MSHA) conducted a joint survey to determine the range of coal particle sizes found in

  • NIOSH
    Explosion Prevention in United States Coal Mines

    By Jürgen F. Brune, R. Karl Zipf, Kenneth L. Cashdollar

    This paper outlines the legal standards and methods for protecting underground coal mines in the United States from explosions of methane gas and coal dust. It will discuss inspection and monitoring o

  • NIOSH
    Trunk Extension Strength and Muscle Activity in Standing and Kneeling Postures

    By Sean Gallagher

    Study Design. A split-plot experimental design was used to evaluate the influence of posture, trunk angle, and rotational velocity on peak torque output and myoelectric activity during maximal trunk e

  • NIOSH
    Airborne Dust Capture And Induced Airflow Of Various Spray Nozzle Designs

    By Douglas Pollock, John Organiscak

    Water spray characteristics, including droplet size and velocity, airborne dust capture potential, and induced airflow quantity for various spray nozzle designs were evaluated to provide basic informa

  • NIOSH
    Assessment Of Present Electromagnetic Techniques For The Location Of Trapped Miners

    By John Durkin

    Field studies have been conducted in a large number of coal mines throughout the U.S. to determine the effectiveness of electromagnetic techniques in locating men trapped underground following a mine

  • NIOSH
    Enhanced Surface Control For Roof And Rib Support

    By Stephen C. Tadolini, Dennis R. Dolinar

    The risk of injury caused by minor roof falls continues to increase in underground mining. Most ground control injuries result from small rock falls that occur in a supported area, but do not involve